Sign in →

Test Code ACETA Acetaminophen

Specimen Collection Information

 Specimen  Min. Test Volume Collection Container
Blood 0.1 mL Light Green (Lithium Heparin) Vacutainer
Gold Vacutainer
Marble Red/Tiger Top Vacutainer

Reference Ranges & Critical Values

Gender Age Range Normal Range Critical Values Units
ALL 0 Minutes – 150 Years 10 - 30 > 300 ug/mL

Interpretive Data

The concentration of acetaminophen in serum or plasma depends on the time of drug ingestion; concomitant drug therapy; sample condition; time of sample collection; and individual variations in absorption, distribution, biotransformation, and excretion. These parameters must be considered when interpreting results. 

 

Toxic manifestations have been observed at serum concentrations >100 ug/mL; however, the toxic range is generally reported at >200 ug/mL. 

 

Toxic concentrations can be more effectively related to post-dose interval; >200, >100, and >50 ug/mL serum concentrations correspond to toxic concentrations at 4, 8, and 12 hours post-dose, respectively.

Specimen Stability

7 days at 2-8°C

Day(s) Performed

Monday - Sunday

CPT(s)

80307

LOIN-C

3298-7