Test Code OATC Cultivated Oat, IgE, Serum
Reporting Name
Cultivated Oat, IgEUseful For
Establishing a diagnosis of an allergy to cultivated oat
Defining the allergen responsible for eliciting signs and symptoms
Identifying allergens:
-Responsible for allergic response and/or anaphylactic episode
-To confirm sensitization prior to beginning immunotherapy
-To investigate the specificity of allergic reactions to insect venom allergens, drugs, or chemical allergens
Method Name
Fluorescence Enzyme Immunoassay (FEIA)
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
SerumOrdering Guidance
For a listing of allergens available for testing, see Allergens - Immunoglobulin E (IgE) Antibodies
Specimen Required
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 0.5 mL for every 5 allergens requested
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Specimen Minimum Volume
For 1 allergen: 0.3 mL
For more than 1 allergen: (0.05 mL x number of allergens) + 0.25 mL deadspace
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 14 days | |
Frozen | 90 days |
Reject Due To
Gross hemolysis | OK |
Gross lipemia | OK |
Special Instructions
Reference Values
Class |
IgE kU/L |
Interpretation |
0 |
<0.10 |
Negative |
0/1 |
0.10-0.34 |
Borderline/equivocal |
1 |
0.35-0.69 |
Equivocal |
2 |
0.70-3.49 |
Positive |
3 |
3.50-17.4 |
Positive |
4 |
17.5-49.9 |
Strongly positive |
5 |
50.0-99.9 |
Strongly positive |
6 |
≥100 |
Strongly positive |
Reference values apply to all ages.
Day(s) Performed
Monday through Friday
CPT Code Information
86003
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
OATC | Cultivated Oat, IgE | 6093-9 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
OATC | Cultivated Oat, IgE | 6093-9 |
Test Classification
This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.Report Available
Same day/1 to 3 daysNY State Approved
YesForms
If not ordering electronically, complete, print, and send an Allergen Test Request (T236) with the specimen.