Test Code Q10 Coenzyme Q10, Reduced and Total, Plasma
Reporting Name
Coenzyme Q10, Reduced and Total, PUseful For
Diagnosis of primary coenzyme Q10 (CoQ10) deficiencies in some patients who are not supplemented with CoQ10
Diagnosis of CoQ10 deficiency in mitochondrial disorders
Monitoring CoQ10 status during treatment of various degenerative conditions, including Parkinson and Alzheimer diseases
This test is not useful for distinguishing primary CoQ10 deficiencies from acquired CoQ10 deficiencies.
Method Name
High-Performance Liquid Chromatography (HPLC) with Electrochemical Detection
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
Plasma HeparinOrdering Guidance
This test provides both reduced and total coenzyme Q10 (CoQ10). For assessment of total only, order TQ10 / Coenzyme Q10, Total, Plasma.
The level of oxidized CoQ10 is affected in specimens with even slight amounts of hemolysis; however, the total Q10 level remains constant. Hemolyzed specimens can be analyzed for total Q10 using TQ10 / Coenzyme Q10, Total, Plasma.
The most reliable test for the diagnosis of primary defects in ubiquinone (ie, CoQ10) biosynthesis is direct measurement of CoQ10 in muscle.
Shipping Instructions
If possible, do not send other tests ordered on same vial of plasma. In doing so, the other tests may have increased turnaround time due to the strict frozen criteria of this assay.
Necessary Information
Patient's age is required.
Specimen Required
Patient Preparation: Fasting (8 hours)
Collection Container/Tube: Green top (lithium or sodium heparin)
Submission Container/Tube: Plastic vial
Specimen Volume: 0.5 mL
Collection Instructions:
1. Immediately after collection, place specimen on wet ice. Maintain on wet ice and process within 3 hours of collection.
2. Centrifuge, aliquot plasma into plastic vial, and freeze immediately.
Specimen Minimum Volume
0.3 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Plasma Heparin | Frozen (preferred) | 14 days | |
Refrigerated | 8 hours |
Reject Due To
Gross hemolysis | Reject |
Gross lipemia | Reject |
Gross icterus | OK |
Reference Values
COENZYME Q10 (CoQ10) REDUCED
<18 years: 320-1376 mcg/L
≥18 years: 415-1480 mcg/L
CoQ10 TOTAL
<18 years: 320-1558 mcg/L
≥18 years: 433-1532 mcg/L
CoQ10 % REDUCED
<18 years: 93-100%
≥18 years: 92-98%
Miles MV, Horn PS, Tang PH, et al. Age-related changes in plasma coenzyme Q10 concentrations and redox state in apparently healthy children and adults. Clin Chim Acta. 2004;34:139-144
Day(s) Performed
Monday through Friday
CPT Code Information
82542
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
Q10 | Coenzyme Q10, Reduced and Total, P | In Process |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
87853 | CoQ10 reduced | 81157-0 |
30091 | CoQ10 Total | 27923-2 |
30092 | CoQ10 % reduced | 81156-2 |
30159 | Interpretation | 59462-2 |
Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.Report Available
2 to 4 daysNY State Approved
YesForms
If not ordering electronically, complete, print, and send a Biochemical Genetics Test Request (T798) with the specimen.