Test Code RT3 T3 (Triiodothyronine), Reverse, Serum
Reporting Name
T3 (Triiodothyronine), Reverse, SUseful For
Aiding in the diagnosis of the sick euthyroid syndrome
Method Name
Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)
Portions of this test are covered by patents held by Quest Diagnostics.
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
SerumSpecimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube:
Preferred: Red top
Acceptable: Serum gel
Submission Container/Tube: Plastic vial
Specimen Volume: 0.8 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Specimen Minimum Volume
0.4 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 28 days | |
Ambient | 28 days | ||
Frozen | 28 days |
Reject Due To
Gross hemolysis | Reject |
Gross lipemia | OK |
Gross icterus | OK |
Reference Values
10-24 ng/dL
Day(s) Performed
Monday through Friday
CPT Code Information
84482
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
RT3 | T3 (Triiodothyronine), Reverse, S | 3052-8 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
9405 | T3(Triiodothyronine),Reverse,S | 3052-8 |
Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.Report Available
2 to 6 daysNY State Approved
YesForms
If not ordering electronically, complete, print, and send a General Request (T239) with the specimen.